Chauvin Arnoux ML912 2-channel current logger with flexible sensors

Electrical Specification
- Channels: 2
- Input connection: Integral MiniFlex™ flexible AC current sensors
- Range: 0.5 - 100 AAc / 5 - 1000 AAc
- Resolution: 0.1 A
- Accuracy : 0 - 1 A: không cụ thể ; 1 - 100 A: ±(1 % R + 0.5 A) / 0 - 5 A: không cụ thể  ; 5 - 1000 A: ±(1 % R + 1 A)
- Sample rate: 64 samples/cycle
- Storage rate: Programmable from 125 ms to 1 day
- Storage modes: Start/Stop, FIFO and Extended Recording Mode (XRM™) 
- Recording length: 15 minutes to 8 weeks, programmable using DataView®
- Memory: 240,000 measurement (512 kB). The recorded data is stored in non-volatile memory & retained even if the battery is low or removed
- Communication: USB 2.0 optically isolated
- Power source: 2 x 1.5 V AA-cell alkaline batteries
- Battery life: 100 hours to > 45 days (depending on storage rate/recording length)
Mechanical Specification
- Dimensions: 136 x 70 x 32 mm (5.38 x 2.75 x 1.28")
- Max conductor size: Depends on current probe
- Weight (with battery): 245 g (8.67 oz)
- Safety rating: IEC 61010-1 ; 600 V CAT III ; 300 V CAT IV ; Pollution degree 2
- Casing: UL94-V0
- Vibration: IEC 60068-2-6 (1.5 mm, 10 to 55 Hz)
- Shock: IEC 60068-2-27 (30G)
- Drop:  IEC 60068-2-32 (1 m)
Environment Specification
- Operating temperature: -10 to +50 °C 
- Storage temperature: -20 to +60 °C 

State at delivery:  type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. 

Details

datasheet
user guider

Advantages

  • 2-channel current logger
  • Own power supply

Description

For network monitoring,the ML912 logger acquires 64 samples per period. Frequency monitoring is performed on a range of ±2 Hz around the network's rated frequency (50 ou 60 Hz). The harmonic measurements are calculated from these 64 samples (available in the DataView® software). This Simple Logger® II model stores the TRMS values up to 8 times per second depending on the storage interval programmed by the user. The TRMS calculations are performed on a single period.

Specifications

  • 1 to 1,000 AAC
  • 2 ranges: 100 and 1,000 AAC
  • 152mm sensors
  • Battery-powered
  • USB link
  • Compatible with DataView®
  • Number of measurements: 240,000
  • Sampling rate: 64 per period
  • Recording rate from 8 measurements/s to 1 measurement/day
  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information