GFUVE GF3600 三相AC-DC电表校准器 (AC 800V 100A; DC 1000V 30A)
制造商: GFUVE Model: GF3600 来源: China 保障: 12 Month - 报价要求
- 联系
ELECTRICAL PARAMETERS
Accuracy class : 0.05%, 0.1%
Power supply: AC 220V ± 10% or AC 110V ± 10%, 50/60Hz
AC Voltage output and measurement
U1, U2, U3 Range: 10V, 20V, 50V, 100V, 200V, 400V, 800V
Output range: (0-120%)% RG
Adjustment resolution: 0.01% RG
Output stability: 0.01%/min
Measurement accuracy: 0.05% RG
Output load capability: 50VA
Measurement resolution: ≤5×10-5 RG
AC Current output and measurement
I1, I2, I3 Range: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A
Output range: (0-120)% RG
Adjustment resolution: 0.01% RG
Output stability: 0.01%/min
Measurement accuracy: 0.05% RG
Output load capability: 100VA
Measurement resolution: ≤5×10-5 RG
Power output and measurement
Output stability: 0.01%/1min
Active accuracy: 0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C)
Reactive accuracy: 0.1% RD (0.01A-100A, 30V-600V, PF ≥0.5)
Measurement resolution: ≤5×10-5 RG
Energy measurement
Active accuracy: 0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C),
0.1% RD (0.05A-100A, 30V-600V PF ≥0.5C)
Reactive accuracy: 0.1% RD 0.05A-100A, 30V-600V PF ≥0.5
Setting range of test pulse No.: 1-9999999
Max. frequency of receiving pulse: 2MHz
Phase output and measurement
Output range: 0°-359.99°
Adjustment resolution: 0.01°
Measurement accuracy: 0.05°
Measurement resolution: 0.001°
Power factor output and measurement
Output range: -1 to 0 to +1
Measurement accuracy: 0.0005
Measurement resolution: 0.0001
Frequency output and measurement
Output range: 45-65Hz
Adjustment resolution: 0.001Hz
Measurement accuracy: 0.005Hz
Measurement resolution: 0.001Hz
Harmonic
Times: 2 to 31
Resolution: 0.1% (compared with fundamental wave)
Contents: 0-30%
Phase: 0°-359.99°
DC Voltage output
Range: 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 300V, 600V, 1000V
Setting range: 0-1000V
Regulated step value: 0.002% RG
Accuracy: 0.03% RD + 0.02% RG
Stability: 0.01%RG/1min
Output load capability: 25VA
Ripple wave and noise: 0.1-100KHz
Output ≤100 V: Ripple wave ≤2mVrms
Output > 100 V: Ripple wave ≤10mVrms
DC Current output
Range: 10μA, 30μA, 100μA, 300μA, 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1 A, 3 A, 10 A, 30 A
Setting range: 0-30A
Regulation resolution: ≤0.02% RG
Accuracy: 0.03% RD + 0.02% RG
Stability: 0.01%RG/1min
Output load capability: 30VA
MECHANICAL PARAMETERS
Dimension (L×W×H) (mm): 1800x800x750
Weight (kg): 135
ENVIRONMENTAL CONDITIONS
Operating temperature: 0°C to 40°C
Relative humidity: ≤85%